Slit Actuator – 500N, 24V, 1.1A, 285mm Stroke EA-L/S

Slit Actuator – 500N, 24V, 1.1A, 285mm Stroke EA-L/S

Electromechanical slit actuator, type EA-L/S-500/300-02
Tested to DIN EN 12101-2. Voltage 24 V DC, rated current 1.2 A, nominal force 500 N, IP 20, switch-on duration 30%, running speed at nominal load 8.4 mm/s, integrated electronic load shedding and potential advance “F”, as well as built-in position-independent stop damping, in continuous aluminum Profile tube, housing anodized E6 / EV1, with cable entry on the motor housing cover, incl. 3.0 m silicone connection cable SIHF 3 x 0.75 mm², light gray, integrated housing for flexible bracket system in the motor housing. Overall length of motor housing: Stroke + 284 mm + 20 mm (cable insert), Stroke 285 mm, incl. Rear bearing, Type HK-L and setting angle, Type AW-80-S.

£284.70

Description

The slit actuator type EA-L/S-500/300-02, which has been specially modified for louvre windows, in conjunction with a TG-24 (RWA) glass louvre, is considered to be the optimum solution both in the smoke and heat extraction area and as an air supply system. Even with small stroke lengths, large opening widths can be achieved.
Perfect smoke and heat extraction actuator for bottom hung wings and rotary wings
In addition to the automatic overload cut-off under load, the integrated electronics also take over a torque control by monitoring current consumption to the force curve. After technical inspection, the slit actuator is also suitable for turning and swinging wings. It is recommended that the slit actuator be combined with an additional electrical locking type ZVE-UNI-I / A to lock the window adequately.
This slit actuator is particularly well suited for use on large bottom hung wings and rotary wings. An integrated electronic overload cut-off prevents damage to the gearbox by automatically switching off the actuator in the event of an overload.
Your benefits at a glance:

unique opening kinematics via deployment angle
60° opening within the soffit – also possible over 140° opening
for inward and outward opening bottom hung wings and rotary wings
integrated electronic overload cut-off
integrated safety shutdown
can be combined with additional electrical locking ZVE-UNI-I / A
Under the Construction Products Regulations (CPR) it is a legal requirement to use only certified products for smoke ventilation. It is the responsibility of the installer to ensure installations meet the relevant standards. For more information see SCS Group’s Technical Bulletin.

Additional information

Brand Name

SIMON PROtec